Home > Error Binding > Error Binding Socket Address 10048

Error Binding Socket Address 10048

Contents

A situation where this might be a problem is if my program is trying to find a reserved local port (< 1024) to connect to some service which likes reserved ports. For me the issue was that I had a vbs script testing NTP with the w32tm command, and this had crashed. Jun 17 '11 at 1:02 4 this has enough information. WSA_OPERATION_ABORTED 995 Overlapped operation aborted. http://megavoid.net/error-binding/error-binding-to-socket-10048.html

Figure 1 Figure 1 shows all of the possible states that can occur during a normal closure, depending on the order in which things happen. You should be passing and ip/port to connect(). Would PRC extend its Panda policy to Mars colonist? Difference between a Lindlar and Rosemund catalyst My math students consider me a harsh grader.

Error Binding Socket Address 10048

The FormatMessage function can be used to obtain the message string for the returned error. By the way, if you don't have XP Pro try using the site "time.nist.gov" and use Protocol: Time/tcp. I still have to wait for around 1min30secs before I can actually reuse that port. –Tu Hoang Jun 17 '11 at 1:11 | show 5 more comments up vote 16 down The program provides SNTP, port 123 (almost all sites).

Free PRTG Download >> What is this? Returned when a system call that should never fail does fail. Syntax Design - Why use parentheses when no arguments are passed? Error Binding Socket Address Already In Use A connect request was made on an already-connected socket.

An invalid QoS flow descriptor was found in the flow descriptor list. Disclaimer: The information in the Paessler Knowledge Base comes without warranty of any kind. Oddly, using SO_REUSEADDR can actually lead to more difficult "address already in use" errors. http://stackoverflow.com/questions/31912162/wsa-error-10048-when-binding-server-sockets What is the success probability for which this is most likely to happen?

How Do I Restore Downloads in Netscape 4.0 9. Error Binding Socket Addr='af_unix(/dev/log)' Error='address Already In Use (98)' The attempted operation is not supported for the type of object referenced. more stack exchange communities company blog Stack Exchange Inbox Reputation and Badges sign up log in tour help Tour Start here for a quick overview of the site Help Center Detailed For instance, if the length of an argument, which is a sockaddr structure, is smaller than the sizeof(sockaddr).

Windows Socket Error 10048 On Api Bind

The application protocol must be designed so that the client knows when to close. How do hackers find the IP address of devices? Error Binding Socket Address 10048 Note that this error is returned by the operating system, so the error number may change in future releases of Windows. Error 10048 Only One Usage Of Each Socket Address WSA_QOS_EPSFILTERSPEC 11028 Invalid QoS provider-specific filterspec.

An invalid shaping rate object was found in the QoS provider-specific buffer. http://megavoid.net/error-binding/error-binding-socket-address-already-used.html For more information, please refer to the following Microsoft KB article. Yes No Additional feedback? 1500 characters remaining Submit Skip this Thank you! A couple of solutions come to mind. Socket Error 10048 Maya

What? Could not bind socket 12. 'CANNOT BIND SOCKET' 13. While you can check the connections using a select() call before closure, a tiny but real possibility exists that a connection could arrive after the select() but before the close(). http://megavoid.net/error-binding/error-binding-to-socket-failed-errno-10048.html This is also true if the application dies while a connection is pending.

Visit our UserVoice Page to submit and vote on ideas! Error Binding Socket Addr='af_inet The call has been canceled. WSAEINVALIDPROCTABLE 10104 Procedure call table is invalid.

share|improve this answer answered Jun 5 '13 at 12:10 user2455528 211 add a comment| up vote 1 down vote I know you've already accepted an answer but I believe the problem

Missing SmartMarks 3. The Windows function is indicating a problem with one or more parameters. WSAEINVALIDPROVIDER 10105 Service provider is invalid. Error Binding Socket (3420) On Windows the default limitation is 5000 - 1024 open sockets (5000 is the default max user port setting and the first 1024 ports are reserved).

In many cases simply waiting a few seconds before the server closes will be adequate. WSA_E_NO_MORE 10110 No more results. WSAEDESTADDRREQ 10039 Destination address required. Check This Out Jun 17 '11 at 0:17 Because I have to put that into a production server, and in that server, all outgoing connections are blocked.

This might be OK but bind() and shutdown() don't seem to play well together. WSA_QOS_BAD_STYLE 11012 QoS bad style. In some instances, it also refers to the current state of the socket—for instance, calling accept on a socket that is not listening. What should I do?

Why are there so many different amounts received when receiving a payment? killing processes using given port %d, %s"%(PORT_NUMBER,e) os.system("xterm -e 'sudo fuser -kuv %d/tcp'" % PORT_NUMBER) serve() raise e share|improve this answer answered Apr 3 '14 at 13:52 test30 1,3651318 add a WSAENAMETOOLONG 10063 Name too long. An invalid QoS provider-specific buffer.

On some operating systems it allows the same port to be used with a different address on the same machine by different processes at the same time. WSA_QOS_EFILTERCOUNT 11021 Incorrect QoS filter count. WSAESTALE 10070 Stale file handle reference. HKLM\System\CurrentControlSet\Services\Tcpip\Parameters\TCPTimedWaitDelay is the key to use.

Make a suggestion Dev centers Windows Office Visual Studio Microsoft Azure More... I'm really not sure why this state isn't necessary on the other side, when the remote end initiates closure, but this is definitely the case. WSAECONNABORTED 10053 Software caused connection abort. After these changes are made the system must be restarted.

SNTP worked fine for me in Windows ME, but not in Windows XP Pro get the basted error message. The max by default is 5000. I can kill those, but there is always at least one 5666 and 12489 port in listening state, held open by System, which I can't kill. No connection could be made because the target computer actively refused it.

asked 1 year ago viewed 780 times active 1 year ago Related 0Different between none-blocking mode with async socket in C++ winsock server0WinSock2 bind error0Winsock select error 10038, bind and listen A required address was omitted from an operation on a socket.